Set your preference
Font Scaling
Default
Page Scaling
Default
Color Adjustment
IITK
IITK

High speed combustion data acquisition system for recording pressure-crank angle signals from the engine combustion chamber.


Research Areas

  • To acquire in-cylinder pressure data, engine tuning, combustion analysis and troubleshooting.
  • Hardware for this data acquisition system consists of National Instrument BNC 2090 adapter, National Instrument MIO16E1 data acquisition card and a computer.
  • The function of BNC 2090 adapter is to simplify the connection of analog signals and digital signals to the DAQ board. BNC 2090 can be configured to use eight differential or 16 single ended analog input channels available.
  • The program for data acquisition was developed using National Instruments LabVIEW 8.6 software. In this DAQ system, TDC signal was used to trigger the data acquisition system. Crank angle signals from the shaft encoder were used by the program to operate in external clock mode.

Contact Person

  • Dr Avinash K Agarwal,
    FSAE, FASME
    Department of Mechanical Engineering
    Indian Institute of Technology Kanpur
    Kanpur-208016 India
    Home Page: www.iitk.ac.in/erl
    Tel: +91 512 2598682 (Res)
    Fax: +91 512 2597982, 2597408 (Off)
  • +91-512-259-7982

Access procedure:

 Prof. Avinash Kumar Agarwal

Location Info:

Engine Research Laboratory, IIT Kanpur

Timings:

Avinash Kumar Agarwal

Any Other Key Information:

  • In this data acquisition system, programming was done in LabVIEW to acquire pressure data and then post-processing was done. Thus one can change or modify the program according to the desired output parameters.

Contact info:

Engine Research Laboratory
Department of Mechanical Engineering
IIT Kanpur, Kanpur-208016

Tel: +91 512 2597458 (Lab)

Kewords: